Hello All,
We are having some problem with my HP Prolient DL380 G6 server, running on windows server 2008 std,
Problem : i can not install any update or can not open any role for this server, when ever i try to do so, the following error showing
1. Log Name: System
Source: disk
Date: 3/15/2016 7:55:34 AM
Event ID: 11
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: Sxxxxxxxxx.dom
Description:
The driver detected a controller error on \Device\Harddisk0\DR0.
2. Log Name: System
Source: Cissesrv
Date: 3/15/2016 7:55:33 AM
Event ID: 24606
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: xxxxxxxx.dom
Description:
Logical drive 1 configured on array controller P410i [Embedded] returned a fatal error during a read/write request from/to the volume.
Logical block address 246264, block count 8 and command 32 were taken from the failed logical I/O request.
Array controller P410i [Embedded] is also reporting that the last physical drive to report a fatal error condition (associated with this logical request), is located on bus 0 and ID 0.
We are having some problem with my HP Prolient DL380 G6 server, running on windows server 2008 std,
Problem : i can not install any update or can not open any role for this server, when ever i try to do so, the following error showing
1. Log Name: System
Source: disk
Date: 3/15/2016 7:55:34 AM
Event ID: 11
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: Sxxxxxxxxx.dom
Description:
The driver detected a controller error on \Device\Harddisk0\DR0.
2. Log Name: System
Source: Cissesrv
Date: 3/15/2016 7:55:33 AM
Event ID: 24606
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: xxxxxxxx.dom
Description:
Logical drive 1 configured on array controller P410i [Embedded] returned a fatal error during a read/write request from/to the volume.
Logical block address 246264, block count 8 and command 32 were taken from the failed logical I/O request.
Array controller P410i [Embedded] is also reporting that the last physical drive to report a fatal error condition (associated with this logical request), is located on bus 0 and ID 0.